County says east pond plugged and being aerated; west pond to be pumped and dredged; storage tank inspected, no leak found

3331742 · May 16, 2025
AI-Generated Content: All content on this page was generated by AI to highlight key points from the meeting. For complete details and context, we recommend watching the full video. so we can fix them.

Summary

Republic reported the east pond was plugged after a seep, is being aerated and will be sampled; the west pond is being pumped and will be dredged once drained. A above-ground storage tank that had floated was dewatered and was being inspected; temporary frac-tanks are on-site as contingency storage.

Republic representatives updated the commission on stormwater and leachate-impacted ponds and on an above-ground storage-tank incident.

East pond: staff said a seep was identified and the pond was plugged. They reported a “low level exceedance” of some stormwater parameters, are aerating the pond, and plan to sample it after roughly two weeks of aeration to allow chemistry to equilibrate.

West pond: staff said pumping difficulties at the existing lift station required bringing in a contractor (Rain for Rent) and a pumping system that can treat leachate and stormwater and route discharge to the publicly owned treatment works (POTW). Once the pond is drained the on‑site contractor will dredge and collect bottom soil samples for analysis; staff said dredging is expected once the pond can be kept sufficiently dewatered, likely within about two weeks if weather cooperates.

Storage tank: staff reported that on April 30 a tank appeared to have floated in its secondary containment. Teams dewatered the containment so the tank would settle upright. The tank showed no signs of leaking. The tank will be cleaned and inspected by the constructing contractor, Southeastern Tank Services (AquaStore materials), with an inspection report to follow. Two 20,000-gallon frac tanks with secondary containment are staged on site as contingency storage.

Ending: Staff said they will sample and report on pond chemistry, provide dredging schedules, and circulate the tank contractor27s inspection findings when available.