Developer returns with revised layout for East 20 First project after earlier denial; commissioners flag slopes and access

3585786 · May 16, 2025
AI-Generated Content: All content on this page was generated by AI to highlight key points from the meeting. For complete details and context, we recommend watching the full video. so we can fix them.

Summary

A sketch plan for a five-story, 35-unit building at East 20 First Street was discussed; staff and the applicant described revisions to improve fire and vehicle circulation and asked for additional details on retaining walls, stormwater and screening.

The commission reviewed a sketch plan to consolidate six lots at 921–933 East 20 First Street and construct a roughly 7,000-square-foot, five-story building containing 35 dwelling units (11 one-bedroom and 24 two-bedroom units). The plan shows 47 ground-level parking spaces (including two ADA spaces) and 14 spaces in a basement garage.

Background and context: Planning staff noted the project had previously been reviewed as a preliminary final plan in mid-2024 and was denied by city council in October 2024. The new sketch seeks improved circulation and addressing prior concerns. The site is wooded and slopes down toward Ridley Creek; steep slopes ranging from 15–25% were documented on the plan.

Applicant’s revisions: The applicant said the new layout provides full circulation around the building for fire and trash trucks, relocates a garage entrance previously on the front of the building, and shows a dumpster pad accessible by a trash truck so pickups can be made without reversing into the street. The applicant also described proposed retaining walls and guide rail/fall-protection fencing for changes in elevation.

Staff concerns: Planning staff asked for additional landscape buffering (evergreens) to screen the building from adjacent homes and asked that utilities be placed underground. The city engineer raised typical engineering concerns: driveway slope limits (maximum 10% within 20 feet of a street right-of-way), retention/infiltration testing for stormwater, and avoiding infiltration upgradient of the building foundation. Fire access and potential need for sprinklering in a multiunit building were also raised.

Next steps: The item was reviewed as a sketch plan; staff asked the applicant to provide formal turning templates for fire and trash apparatus, additional stormwater testing and a tree-protection/debris-management plan for the steep site before a preliminary/final plan is submitted for formal review.