County updates investigation of electric bus thermal event; two buses cleared for return to service

3287497 · May 13, 2025
AI-Generated Content: All content on this page was generated by AI to highlight key points from the meeting. For complete details and context, we recommend watching the full video. so we can fix them.

Summary

Following a January thermal runaway event on one electric bus, county staff and external engineers determined contactor welding and battery imbalance caused the incident; two newer-generation buses were reprogrammed and will be returned to service, while one destroyed bus remains salvaged under FTA/insurance process.

County transit staff reported the results of a multi-party investigation into a thermal-runaway event affecting an electric transit bus in January. The county said insurance-hired engineers, the bus manufacturer and county fleet technicians all reached the same conclusion about the cause: an electrical contactor welded closed during charging, creating an imbalance across battery banks that led to overheating and thermal runaway.

Transit maintenance staff credited an in-house technician who first identified the fault pattern;…