Board denies request to reduce septic design flow for 2 and 4 Blueberry Drive; requires tank upgrade if constructed

AI-Generated Content: All content on this page was generated by AI to highlight key points from the meeting. For complete details and context, we recommend watching the full video. so we can fix them.

Summary

The Board of Health denied a variance request to use reduced water-usage records to downsize septic design flows for a combined system at 2 and 4 Blueberry Drive. The board also noted that an existing 1989 single-compartment tank must be replaced if the combined system proceeds.

Joseph Sander of Allen Majors Associates presented a proposal to combine and replace septic systems serving 2 and 4 Blueberry Drive and asked the Board of Health to accept reduced water-usage records as the basis for a lower design flow for the proposed septic system.

Sander said meter records show about 50 gallons per day per unit for the elderly-occupied properties and that using those records would yield a design flow of roughly 307 gallons per building (after the standard 200% allowance noted in guidance) and about 1,200 gallons per day for the combined system. He told the board the owner wanted to combine two small elderly-occupancy buildings to capture an economy of scale and proactively replace aging systems.

Board members reviewed Title 5 language (310 CMR 15.203) and expressed concerns about relying on meter records to substantially reduce the standard design flows for multi-unit or senior-occupancy facilities. One board member said the neighborhood had a history of system failures and expressed concern that undersizing would shorten system life. The board also reviewed subsurface test pits and noted an area of deep fill and inconsistent soils; the applicant said test pits showed four feet of naturally occurring pervious soil in the proposed placement after walking the field location.

Separately, board staff flagged that a 2,500-gallon septic tank on one property appears to be a single-compartment tank installed in 1989; under local practice a two-compartment 3,000-gallon tank would be required to meet current flows and Title 5 expectations if the combined system proceeds.

Outcome: A board member moved to deny the waiver to reduce the design flow to the requested lower rate (motion language referenced a reduction to 75 gallons per day in the motion record), the motion was seconded and approved by voice vote. The board advised the applicant that, if the applicant returns with a revised plan, the plan should show the relocated field that avoids fill and utilities and include the required tank replacement and two-compartment configuration as part of any future approval.

Why this matters: The decision preserves Title 5 design-flow standards for multi-unit or elderly-occupancy facilities in Lakeville and prevents a smaller-than-standard field that the board expressed concern could fail earlier than a system sized to Title 5 flows.

Next steps: The applicant may return with a revised plan that relocates the field away from fill, shows the 3,000-gallon two-compartment tank upgrade, and meets standard Title 5 flows if they wish to proceed. The board recorded that the existing system at one of the properties is not currently in failure.