Get Full Government Meeting Transcripts, Videos, & Alerts Forever!
Get email alerts on the Facilities Infrastructure topic
No spam. Unsubscribe anytime.
Board approves schematic design for new maintenance and warehouse facility at former Higginbotham site
Summary
Trustees approved schematic designs to convert a 17,000-square-foot pre-engineered building on Highway 29 into a consolidated maintenance, warehouse and operations center with a secure professional-development room, district nurse space and a police department suite.
Get email alerts on the Facilities Infrastructure topic
No spam. Unsubscribe anytime.
The Liberty Hill ISD board approved schematic designs Wednesday for a new maintenance and warehouse facility at the district’s recently purchased former Higginbotham building on Highway 29.
Designers and district staff told trustees the 17,000-square-foot pre-engineered metal building has “good bones” for conversion and will provide conditioned workshop space, expanded warehouse storage and a secured front vestibule. The schematic includes a professional-development room intended to serve as an emergency power–capable technology hub and an interior “shelter” space designed to meet storm-shelter needs for users of the facility.
Key features and rationale
- Use of existing structure: Architects recommended adapting the purchased metal building to reduce cost while adding interior office, nurse and police department space.
- Program spaces: The design includes conditioned shop space, a larger warehouse (roughly double the district’s current conditioned storage), a professional-development room sized about two classrooms, a district-nurse office, a staff break room and a secured area for the district police office and evidence/storage.
- Alternate work: Designers proposed a small enclosed attic-stock storage area as an alternate bid item and three covered outdoor storage bays.
- Schedule and next steps: The board approved schematic designs; staff will proceed to design development and construction documents, target contractor selection in April–May and anticipated a construction completion date in November 2025. Presentation materials noted no construction costs were being approved at schematic stage.
Board discussion and action
Trustees asked whether the facility would include a loading dock; architects said the district’s delivery patterns and equipment made a loading dock an unnecessary cost. Trustees also discussed the facility’s role as a base for the district police chief and the site’s relative security; district leaders said the police chief will remain engaged on campuses and the facility would serve as an administrative base rather than a campus command post.
Trustee Hargrove moved to approve the schematic design; Trustee Neighbors seconded the motion. The board voted to approve the schematic as presented.
Provenance: The schematic design presentation and board approval took place during the meeting’s action items (schematic design discussion in agenda item 8a, approval recorded under the action item vote).

