Get Full Government Meeting Transcripts, Videos, & Alerts Forever!
Get email alerts on the Annexation topic
No spam. Unsubscribe anytime.
Developer proposes 78 units along Hals Hill Pike; staff flag drainage, access and small-area study requirements
Summary
Harpeth Valley Homes presented a conceptual annexation and zoning request for roughly 17.5 acres along Hals Hill Pike proposing about 78 units (a mix of townhomes and detached homes). Staff said the property is outside the service‑infill boundary and would require a small‑area study to be annexed; drainage, sinkholes and a single primary access
Get email alerts on the Annexation topic
No spam. Unsubscribe anytime.
Harpeth Valley Homes presented a conceptual plan to annex and zone roughly 17.5 acres along Hals Hill Pike for approximately 74–78 units, a mixture of attached townhomes and detached single‑family homes. Staff said the site is outside the city—s service-infill boundary and therefore would require a small-area study to evaluate whether the boundary should be moved before formal annexation.
Matt Taylor, representing the applicant, said the design intends a roughly 50/50 mix of attached and detached housing and showed concept renderings of alley‑loaded attached units and lower‑density detached houses. Taylor said the proposal would retain open space and existing sinkholes in place where possible and rely on engineered drainage improvements to move stormwater to an existing box culvert constructed with prior Hals Hill Pike improvements. He displayed a May 2010 flood photograph to illustrate historical flooding in the area and said engineered solutions would be part of any later formal plan.
Staff and the applicant described the site as flat, rocky and containing sinkholes; county engineers raised concerns about how quickly water leaves the property and the need for a drainage easement that the applicant said they would not execute until development-level engineering was complete. The applicant said existing drainage features and new engineered swales would be used to route water; staff acknowledged that good engineering typically improves these patterns but said the county had identified drainage-rate concerns that need resolution.
On utilities, staff said current sewer capacity would handle the proposed development but cautioned that capacity could be constrained if additional nearby properties seek service later. Commission and council members flagged that the concept showed a single primary vehicle access and asked staff to consult the fire department about emergency ingress/egress and whether an additional emergency access would be required. The applicant said the project would likely be submitted as a PRD to allow the city to require architectural and landscape commitments.
No formal petition or vote occurred; staff instructed the applicant that a small-area study and departmental reviews (public safety, schools, sewer, drainage) are prerequisites for any annexation and zoning application.