Carmel committee weighs buffer, drainage and parking details for 27-unit townhome PUD, continues item to Jan. 6
Summary
Committee members reviewed a proposed 27‑unit townhome PUD in Carmel, focusing on buffering next to the Forte medical facility, limitations from drainage and sanitary easements, street design (inverted crown), parking counts and rental restrictions; staff recommended continuing the item so the applicant can add required PUD text and exhibits.
Get email alerts on the Land Use topic
No spam. Unsubscribe anytime.
A Carmel planning committee spent its meeting dissecting design constraints and PUD text for a proposed 27‑unit townhome development, with the central tensions centered on how to screen the project from the adjacent Forte medical facility, where easements limit planting, and how street and parking choices affect long-term maintenance.
Speaker 1 opened by asking whether the rear elevations’ dormers could be replicated; the applicant’s representative (Speaker 2) said the treatment had not been raised previously and asked to see final design visuals before committing. Committee members raised sight-line and aesthetic concerns for the north buildings facing Forte and suggested alternative treatments such as louvers or lighter window film to avoid a stark black appearance.
Why it matters: the project sits immediately adjacent to an active medical facility and a state-controlled right of way. Committee members said the visual impact and ability to provide tree buffering will shape both the PUD’s text and public reception, and could require coordination with Forte or with the State Highway Department.
On buffer, easements and trees: the applicant told the committee that code requires roughly 10 trees per acre and that the Carmel standard for a rear drainage easement is typically 30 feet, but the team proposed a 20‑foot drainage easement in lieu of 30 feet with required buffer plantings sited as close to the northern property line “within 3 feet” of that line where possible (Speaker 2). The record shows portions of the site are covered by a sanitary easement where trees cannot be planted; Speaker 4 and others made clear that any planting in the gray area on the exhibit would be subject to State Highway Department approval, not city control.
Forte’s concerns: committee members relayed a recent meeting with Angie Stevenson at Forte, who, according to the applicant’s account, said Forte’s clinicians were “concerned about the buffer” and wanted screening. The applicant offered three options if plantings can’t be placed on the project site: work with Forte to plant on Forte property; install a privacy fence; or accept limited planting and a masonry or brick wall in strategic locations.
Street and stormwater tradeoffs: committee members repeatedly criticized the proposed inverted‑crown street section, arguing inverted crowns and private‑street configurations often lead to longer‑term maintenance problems and potential city costs if private streets are later converted to public. The applicant said the inverted crown was chosen to preserve a 24‑foot travel width plus 6‑foot tree lawns and sidewalks on both sides, and that reverting to a traditional curb-and-gutter section would require more north–south width than the site currently allows. The team agreed to explore alternatives with engineering.
Parking, rentals and soundproofing: the applicant said there would be no on‑street parking and noted a guest parking area with 10 off‑street guest spots; each unit would provide two garage spaces and two driveway spaces (Speaker 2), and the application will add explicit PUD text to reflect the parking commitments. The PUD currently includes a short‑term rental ban but does not set a cap on long‑term rentals; several committee members asked that a maximum rental percentage be added to encourage owner occupancy. Committee members also asked about road noise from adjacent Route 31; the applicant said the site is lower than the road by about 22 feet and that the proposed 35‑foot building height and additional insulation measures are intended to mitigate noise.
Staff recommendation and next steps: city staff recommended continuing the item so the applicant can add required PUD text (masonry details, parking language, UDO/ADA compliance language for bike and parking provisions), provide dimensioned exhibits of the north buffer and unit depths, and finalize engineering details for drainage. The committee agreed to return the item at the January committee meeting (scheduled for Jan. 6) to review revised exhibits and updated PUD language.
What was not decided: no formal vote or ordinance adoption occurred. Key outstanding items to be resolved before the committee takes action include (1) PUD text clarifying where masonry will occur beyond the first floor; (2) explicit parking commitments and guest parking signage; (3) a clear approach to screening the north property line that acknowledges areas under state control; (4) whether a rental cap will be included in the PUD.
The committee adjourned with directions to the applicant to return with updated exhibits and PUD language at the next scheduled meeting on Jan. 6.