Wastewater superintendent reports slip-lining, pump upgrades and generator work; solids handling flagged as top concern

New Shoreham Town Council · December 18, 2024
AI-Generated Content: All content on this page was generated by AI to highlight key points from the meeting. For complete details and context, we recommend watching the full video. so we can fix them.

Summary

Wastewater staff said slip-lining has completed about 16,000 linear feet, Old Harbor pump upgrades near completion, SCADA telemetry added and a generator overhaul is scheduled; solids removal and future capacity thresholds were highlighted as critical operational issues.

Wastewater operations remain a priority for town staff, which told the Town Council on Dec. 18 that ongoing slip-lining, pump upgrades and resiliency work aim to reduce infiltration, improve monitoring and secure backup power.

Dylan, the department lead, said the town has completed roughly 16,000 linear feet of slip-lining to address water infiltration and inflow and plans further work over the next five years, primarily funded from sewer reserves. He said Old Harbor pump station effluent-pump upgrades are in final punch-list status but noted variable-frequency-drive (VFD) problems were under investigation.

New SCADA telemetry and ultrasonic transducers now provide remote wet-well monitoring, allowing faster responses to anomalies. Staff also installed bypass piping to maintain flow during pump-station outages.

Dylan said emergency generator work is scheduled: a Milton CAT contractor will complete start-up on Jan. 6, and a second generator is planned for FY2026 with potential January 2026 completion. He emphasized the trade-off of using generators to manage demand charges while weighing maintenance costs.

Operationally, solids handling — removing sludge and transporting it off-island — is the department—s most pressing problem. Current peak treatment approaches of about 310—30 thousand gallons occur once or twice a year; the design threshold noted in discussion was 380,000 gallons, which would require a sustained 90-day overage to change capacity design.

Why it matters: improvements reduce risk of sanitary sewer overflows, increase plant resilience during storms and reduce emergency response times. The council and staff flagged parts procurement lead times and spare-part inventories as ongoing constraints.