Summary

UDA presented revised plans and renderings for an auxiliary gym including a larger weight room, two main courts with cross courts, optional mezzanine and alternatives for windows, HVAC roof screening, goal systems and scoreboards; the board scheduled a work session to finalize equipment choices and vendor questions.

UDA representatives presented revised plans and renderings for a proposed auxiliary gym and led a long discussion with the Tell City-Troy Twp School Corp board about layout, finishes, mechanicals and equipment.

Presenter (S3) opened the presentation with an overview of the site plan and a revised floor plan that showed a larger weight room, optional mezzanine or storage area, concessions and office alternates, and a relocated mezzanine that could also be used for storage. S3 said the revisions preserved future flexibility: "we show a revised floor plan that has some of the updates we talked about before our last meeting." (S3)

Board members questioned clearances and play space. Chair (S1) asked about the court height; S3 and others confirmed the main clearance shown was "25 feet clear," which S3 described as the recommended clearance for basketball. The group discussed court markings and shading: S3 referenced the district's existing Bridal Taylor striping as an example and warned that heavy cross-court striping can make the floor visually busy with multiple lines.

Equipment and safety were recurring topics. Board members pressed for adjustable, motorized goals so younger athletes could practice safely; S3 said vendors offer push-button adjustable goals and that the design team was consulting multiple vendors to identify safety features. The board also discussed scoreboards and wrestling-specific features; S3 noted split/portable scoreboard options and recommended reviewing additional wrestling-oriented add-ons.

Fenestration and security prompted contrasting views. Several members favored daylight and visibility into the weight room; others raised concerns about breakage and student comfort. S3 offered glazing options including reflective coatings, dot-matrix privacy films and higher clerestory windows; ballistic or extra-thick glazing was acknowledged as possible but "very expensive."

Mechanical layout and sightlines were addressed: S3 said the plan includes two larger HVAC units (for redundancy) tucked behind parapet screening so units are not visible from street level. The firm also recommended raising a parapet to screen rooftop equipment and studying decorative screening options.

Storage, mezzanine and future expansion were discussed. S3 noted adding a usable mezzanine would require addressing live-load and egress requirements; an alternative would be taller clear height with pallet-rack storage. The team also sketched how a future third gym could be connected to the current footprint and identified an approximate minimum additional square footage if the district pursues expansion.

Next steps: S3 asked staff to coordinate equipment lists with PE coaches and suggested a short work session to review vendor answers and material samples. The team committed to circulating questions to vendors, returning with samples (brick, panel colors) and refining interior renderings before formal procurement.

Direct quotes from the meeting appear throughout the record and are attributed to the speakers listed in the meeting transcript.