Board requests additional topo, grading and engineering details for 104 Northfield retaining-wall legalization

Planning Board of Dobbs Ferry · April 3, 2026
AI-Generated Content: All content on this page was generated by AI to highlight key points from the meeting. For complete details and context, we recommend watching the full video. so we can fix them.

Summary

An online presenter proposed legalizing a retaining wall and replacing a patio at 104 Northfield Avenue; engineers and staff asked for before/after topography, proposed grading, clarification that the wall should be shown as new (legalization) and sediment/erosion-control details. The board discussed whether the matter requires county referral and set follow-up steps.

An online presenter, Carlos Sosas Trever, described plans to legalize an existing retaining wall (maximum height 3 feet 10 inches), replace a patio with pavers and install a 6-foot white PVC fence at 104 Northfield Avenue.

The consulting engineer (Anthony) asked the applicant to show the wall as a proposed/new wall for the application (because the project seeks legalization), provide existing and proposed topography with a proposed grading plan, and indicate if there is fill or grading changes. Anthony noted that walls under about 4 feet do not usually require engineering calculations unless they retain fill; he recommended the applicant show that the work results in zero net cut/fill by reusing excavation materials and include standard sediment and erosion controls (silt fence) on the drawings.

Anthony also observed an approximate 104-square-foot increase in impervious area and said the site’s gravel behind the wall and provided weep holes may serve infiltration without a separate drywell. Planning staff noted that if the board treats this as a site-plan action it would trigger a county referral because the property is within 500 feet of the Saw Mill Parkway; if the project remains a pre-submission or AHRB matter, those additional steps may not apply.

The applicant agreed to update plans to show existing versus proposed conditions, proposed grading, and to document any excavation/fill so staff can decide whether site-plan approval or AHRB-only review is appropriate at a subsequent meeting.