Commission approves Sea Store site plan and several plats; grants detention waiver for convenience store
Summary
The commission approved final and preliminary plats (Mountain Springs Phase One, Meadow Brook at Cabot, Cutill Road extension, KSS Sea Store subdivision) and granted a site‑plan approval and a waiver of on‑site detention for a Sea Store convenience store at Hwy 367/Hwy 38 after engineers argued detention near an adjacent floodplain was unnecessary.
Get email alerts on the Plats And Siteplan topic
No spam. Unsubscribe anytime.
The Planning Commission approved several plats and a site plan for a new Sea Store convenience store and granted the applicant a waiver from on‑site detention requirements.
Staff presented the final plat for Mountain Springs Phase One (30 lots, two common‑area detention areas) with outstanding water‑department items and pump‑station delivery expected soon; commissioners approved contingent final‑plat approval with staff comments. Commissioners also approved the final plat for Meadow Brook at Cabot, a preliminary plat to extend Cutill Road to Highway 321, and a preliminary plat subdividing property for the Sea Store and a separate floodplain tract near the new overpass.
On the Sea Store site plan, Vernon Williams of Garnet Engineering explained the project: a convenience store just under 6,000 square feet with pumps and a roughly 1,800‑square‑foot restaurant. Williams asked for a waiver of on‑site detention and explained the engineering rationale: because the site discharges directly to a large downstream floodplain reach, designing detention could slow runoff and, in some modeled scenarios, increase peak flows in the floodplain; Williams estimated the boxed detention system would cost the developer roughly $70,000–$90,000. He said pre‑ and post‑runoff estimates for the 100‑year event increased from about 9.5 cfs pre‑development to 15.6 cfs post‑development — a 5.6 cfs difference — but the downstream channel carries flows on the order of 1,400 cfs.
Staff’s outside consultant had raised drainage concerns and asked for additional analysis, but the commission voted to approve the site plan with the requested detention waiver. Commissioners and the applicant also discussed leaving a nearby floodplain parcel undeveloped and agreed to design measures and riprap to protect the site.
All plat and site‑plan items were approved by roll‑call votes noted as unanimous in the transcript.