Planning board asks for grading, stormwater and tree details on Kennedy sketch plan; garage proposed to be built first

Town of Ulysses Planning Board · June 16, 2026
AI-Generated Content: All content on this page was generated by AI to highlight key points from the meeting. For complete details and context, we recommend watching the full video. so we can fix them.

Summary

The board reviewed a sketch plan for a new detached dwelling (1,837 sq ft) and a detached garage (1,456 sq ft) at the Kennedy property, requested a combined house+garage package with grading and erosion control plans, and noted the house may require a variance because of lakeshore setbacks.

At its June 16 meeting the Town of Ulysses Planning Board reviewed a sketch plan for a proposed new detached dwelling and a detached garage at the Kennedy property and requested additional technical documentation before scheduling a final site‑plan review and public hearing.

Applicant Jack Litenberger, appearing on behalf of owners Sha and Janine Kennedy, said the plan calls for a dwelling unit with an 1,837 square‑foot footprint and a detached garage with a 1,456 square‑foot footprint. Litenberger told the board the owners want to build the garage first and defer the house, and that the garage sits outside the wetland/stream setbacks while the house location may trigger a variance or require re‑siting.

Board members stressed the need for a complete grading plan showing limits of disturbance, a stormwater pollution prevention plan (SWPPP) or erosion‑control plan if the project will disturb one acre or more, elevations for the house, and a tree survey that identifies trees above the applicable diameter threshold. The applicant agreed to update the site drawings, correct offsets for the 75‑foot buffer and submit sediment/erosion control and stormwater details before returning to the board.

Staff also clarified that, under the town’s zoning definitions and New York State practice, the 75‑foot lakeshore/stream buffer is measured from the top‑of‑bank/top‑of‑slope (the transcript references the State definition tied to where a slope drops off at about a 45‑degree angle). The board noted that the house may need a Board of Zoning Appeals review if it cannot be relocated outside those setbacks.

Next steps: the board advised the applicant to work with planning staff (including Neil and the town code officer) and engineering consultants to prepare a combined house+garage submission with a grading plan, updated disturbance acreage, tree survey and SWPPP materials; the board suggested the applicant target a subsequent meeting for a final site plan and public hearing once those materials are complete.