Get Full Government Meeting Transcripts, Videos, & Alerts Forever!
Get email alerts on the Land Use topic
No spam. Unsubscribe anytime.
Design review board recommends 7 Brew drive‑through at Thorne and Massillon with conditions
Summary
The board voted to forward a favorable recommendation to the planning commission for a new 7 Brew drive‑through at the Thorne and Massillon Road roundabout, subject to conditions on ingress, screening of rooftop equipment, revised landscaping and a ground‑mounted sign limited to 10 feet.
Get email alerts on the Land Use topic
No spam. Unsubscribe anytime.
The Green City Design Review Board on May 7 voted to forward a favorable recommendation to the planning commission for a new 7 Brew drive‑through at the Thorne and Massillon Road roundabout, with conditions to limit visual impacts and adjust site circulation.
The applicant’s representative, Alan Wiley of GBC Design, outlined a site plan that places a modular 7 Brew building, a cooler behind an awning and a two‑lane drive‑through accessed from CVS Extension Road. “We are looking at constructing a new 7 Brew location on the roundabout of Thorne and Massillon Road,” Wiley said, describing a two‑lane loop with a bypass for pickup and an ADA route to the sidewalk on Thorne Drive.
Architect John Elsey said the building is a compact modular unit intended for efficient drink service with typically four to six employees inside during peak times and walk‑up access at a north door. “The cooler will match the finishes of the main building,” Elsey said, adding that mechanicals and electric meters are located behind screening to minimize visibility.
Board members focused on circulation, parking and visual screening. Members asked the applicant to consider making the north driveway ingress only and to ensure the central aisle remain two‑way so vehicles can exit to the south. The board also pressed for screening of rooftop condensing equipment and year‑round evergreen plantings on the west side of the building to soften sightlines.
The board’s motion, carried by roll call, recommended approval to the planning commission with four conditions: (1) make the north drive an ingress (one‑way) to clarify circulation; (2) screen rooftop and condenser equipment so these units are not visible from the public right‑of‑way; (3) revise the west‑side landscape planting to include year‑round evergreens for consistent screening; and (4) replace the proposed 16‑foot pedestal/pylon sign with a ground‑mounted sign no taller than 10 feet and with a base that complements the building materials.
The board’s recommendation will be considered by the planning commission; the design review board’s action was advisory and does not itself authorize construction.