Ashland approves sewer department purchases including replacement lift-station pump

Board of Aldermen (Ashland, Missouri) · December 17, 2025
AI-Generated Content: All content on this page was generated by AI to highlight key points from the meeting. For complete details and context, we recommend watching the full video. so we can fix them.

Summary

Council authorized the purchase of a replacement pickup truck for sewer operations and approved procurement of a replacement submersible pump for the Northeast Regional Lift Station, opting for a smaller 30-horsepower pump as a cost-saving compromise while staff said it provides needed redundancy.

The Ashland Board approved two items related to sewer operations: a truck purchase for the sewer department and procurement of a replacement submersible pump at the Northeast Regional Lift Station.

Staff requested authorization to purchase a Ford F-150 standard cab pickup from Mockins Ford for $41,264 to replace a vehicle that had been sold before delivery; the action rescinds a prior resolution authorizing a $44,294 vehicle. The board voted to approve Resolution 2025-61.

On the lift-station pump, staff explained that a 64-horsepower pump was damaged in an electrical event in January 2022 and was deemed unserviceable. A direct replacement would cost about $59,574 with lengthy lead times, staff said. The utility director presented an alternative: installing a smaller 30-horsepower pump costing $26,050.20 and addressing control-panel replacement later. "So basically what I did is kind of look through the pump curves...we can get away with a 30 horse at roughly half the cost rather than just put a 64 in there," the utilities staff member said.

Council members asked whether the smaller pump would handle future connections (including a possible airport tie-in) and whether installing a smaller pump could discourage development. Staff and engineering input said the 30-horse option could handle the expected flows and offered a practical compromise while preserving the ability to re-install a larger pump later if development warranted it. The board moved, seconded and approved Resolution 2025-62 to procure the replacement pump.

Why it matters: replacing the pump restores redundancy at a duplex lift station and reduces the risk of costly bypass pumping and potential sewer overflows. The board chose the smaller, lower-cost pump to balance present conditions and budget constraints while acknowledging future upgrades may be needed with substantial development.

Next steps: staff will purchase the approved equipment and schedule control-panel work at a later date; engineering will continue to assess system needs as development and airport connections evolve.