Planning board reviews sketch plan for 15,000 sq ft Vital Signs addition at 764 Ridge Road

Town of Webster Planning Board · August 5, 2026
AI-Generated Content: All content on this page was generated by AI to highlight key points from the meeting. For complete details and context, we recommend watching the full video. so we can fix them.

Summary

MRB Group presented a sketch plan for a 15,000 sq ft addition to an 11,000 sq ft building for Vital Signs; town engineering raised SWIP threshold, oil‑water separator and as‑built record issues to be resolved at preliminary review.

Thomas Schild of MRB Group presented a sketch plan for Galena Development's proposed 15,000 square foot one‑story addition to an existing 11,000 square foot building at 764 Ridge Road. The addition is intended for fabrication of signage products and would disturb about 0.5 acres of the 4.21‑acre lot; the applicant asked for preliminary feedback before returning for preliminary/final review.

Town engineering staff flagged two primary technical items: a local SWIP threshold that the project currently falls just below (25,000 square feet) and the need for the site's oil‑water separator to route to the sanitary system rather than the storm system. The engineer also requested an as‑built of the original building because the approved original site plan lacked the sewer details the sewer department needs. Schild said the site contains an existing pond that handles drainage and that those utility and drainage details will be addressed in the preliminary submission.

The board did not take a vote on the sketch plan; members asked the applicant to resolve the engineering comments and to provide the requested as‑built and sewer connection details before returning for preliminary approval.