Developer seeks changes to 300 Riders Lane approval; proposes sound wall and parking reconfiguration
Oct 29, 2026
Applicant asked the planning board to approve targeted revisions for a previously approved 190-unit project at 300 Riders Lane, citing a new sound wall (up to 30 ft worst-case), parking reorientation, a larger clubhouse and stormwater fixes after beaver damage.
The full story
Middlesex County planning board members on July 1 reviewed proposed revisions to the previously approved 190-unit residential development at 300 Riders Lane. The applicant said the changes are narrowly focused on parking reorientation, a proposed sound wall along the New Jersey Turnpike and an enlarged clubhouse; other elements of the approved plan remain largely intact.
Mister Collins, the applicant’s representative, told the board the project sits on two lots (Lot 1.06 and Lot 1.12) and that the prior approval from 2023 covered 190 units across six residential buildings with 20% affordable housing. He said the principal change driving the application is the relocation of parking because a sound wall (engineers recommended 25–30 feet; Collins put 30 feet on the record as a worst case) along the turnpike requires converting previously angled stalls to parallel parking. "The required amount of parking spaces for the site is 330 spaces. We are proposing that number of spaces with the caveat that we are proposing to share 10 parking spaces from Lot 1.12 with Lot 1.06," Collins said.
The applicant says stormwater management remains almost identical to the previously approved system but recounted a recent operational problem: on-site beaver activity raised basin water levels and partially blocked outflow. Collins said the applicant coordinated with DEP, removed the animals and installed a "beaver deceiver" cage on the outlet to prevent future damming. He agreed to provide a monitoring plan for the basin and to submit a dust-control plan and internal storm-sewer inspection results as requested in the board’s report.
Board professionals requested confirmation of several technical points: exact parking counts after reorientation, the final design and height of the sound wall (the acoustical engineer's final design remains outstanding), and clearance between parallel parking and the wall. The applicant said circulation is largely unchanged but acknowledged one rear drive aisle would narrow from 24 to 22 feet and offered to provide turning templates and fire-department confirmations.