Bicknell officials, school district discuss design changes after new elementary encroaches on town setbacks

3635195 · May 28, 2025
AI-Generated Content: All content on this page was generated by AI to highlight key points from the meeting. For complete details and context, we recommend watching the full video. so we can fix them.

Summary

Town officials and the school superintendent discussed a redesign of a planned elementary school after an expanded kitchen and gym pushed part of the building into required setback and clear‑view zones. No formal action was taken; the district will ask its architect for alternatives before bids are finalized.

BICKNELL, Utah — Town officials and representatives of the school district met May 28 to discuss a planned elementary school after recent design changes left part of the building inside Bicknell’s required setbacks and the town’s clear‑view area.

The meeting focused on a corner of the proposed two‑story elementary where an expanded kitchen, mechanical room and a larger gym added since the original design now sit where Bicknell’s code and state guidance require 24 feet of clear setback; measurements shown to the council indicated roughly 15 feet, 6 inches at the tightest point. The district’s superintendent said the gym and kitchen were expanded after the community and school board asked for a larger facility once federal/state funding arrived and the project moved forward.

Town officials said state law and local ordinance require the municipality to enforce setbacks and clear‑view requirements and that the town cannot legally grant the kind of variance the district requested. With bids opening the next day, participants described a narrow window to make design changes without delaying construction or increasing the price.

Most urgent: what is encroaching and why The school district told the council that early designs — prepared when funding for both a high school and elementary were expected simultaneously — met setbacks. When the elementary was funded later, the district asked architects to expand the elementary kitchen and to add a gym closer to a middle‑school size to meet community requests. The district said those additions, plus a small restroom and a mechanical room placed near a corner door, shifted the footprint and reduced the east‑side setback to well under the town’s 24‑foot clear‑view standard.

Town staff and planning commissioners repeatedly flagged two legal constraints: (1) the town must enforce its land‑use ordinance and state statute language cited in the meeting about municipal compliance with land‑use rules; and (2) the circumstances described do not qualify under the town’s definition of a hardship that would permit a variance (for example, a natural site constraint such as a creek or steep slope). The town’s ombudsman informed staff the council must hold the project to the applicable code, participants said.

Options discussed Participants discussed several technical and administrative options, noting tradeoffs of cost, timing and safety: - Move or reorient the mechanical equipment/door away from the corner to increase the setback from the property line. The council said shifting the mechanical door could reduce the required setback from 12 feet to 6 feet for that portion of wall in some configurations, but that equipment pads and chillers could limit available locations. - Remove a newly added restroom and drinking fountain adjacent to the gym to reduce the campus footprint. District representatives said removing the restroom would require increased supervision during community events but could free enough space to meet the setback. - Reduce or redesign the gym and reconfigure the kitchen so the footprint no longer intrudes. That would require new architectural drawings and potentially large change orders; the superintendent estimated design rework could add “a couple hundred thousand dollars” and risk delaying the project. - Redefine the building’s official “main entrance” (and thus its front setback) to the north side in documents so the required 24‑foot front setback applies on a different axis. Town staff noted the legal setback is defined by the official front entrance listed on plan and paperwork; changing the designated entrance on paper could shift setback calculations but would still require the town to verify compliance across both directions for a corner lot. - Increase off‑street parking within school property and convert nearby district property to additional parking, while preserving curb/gutter and sidewalk improvements the project will bring to the town right‑of‑way.

Council members emphasized safety concerns at the corner where the narrower setback intersects bus and parent drop‑off circulation. Several town members said they could not approve anything that reduced visibility for small children or set a precedent allowing the district to encroach where other property owners could not.

Funding, timeline and responsibility District representatives said some of the additional design and construction work already has been paid for — new drawings, engineering and other design changes were made after the board decided to expand the kitchen and gym when funding became available. The superintendent said interest earned on previously reserved funds and more competitive contractor interest since the high‑school build had made the expansion financially feasible, but that the district would prefer not to delay construction. Bids were scheduled to open the day after the meeting.

Council members and the district discussed whether the architect and engineer had failed to check setbacks after later design changes; several town officials said they expect the design team to bear responsibility for redesign costs if the plans do not meet municipal requirements. The district said its contractor (general contractor Hogan Construction) and the architect had been cooperative on the high‑school project and that the architect was willing to work on revisions; the architect from the St. George office had been invited to join by phone but did not attend in person that day.

Traffic, parking and pedestrian safety The meeting also addressed bus loading, parent drop‑off patterns and sidewalks. The plans show a dedicated bus drop‑off area intended to keep buses off the main road and a separate parent drop‑off; officials said the plan should keep bus and parent flows separate. Town staff and the district discussed installing a four‑way stop at nearby intersections, adding a sidewalk along the east side to the highway, a crosswalk and school‑safety devices (flashing lights and crossing guards) on Main Street. The town urged the district not to mark regular parking stalls in the area intended primarily for bus circulation.

What happened next (directions) No formal approvals or votes were taken. The district superintendent said he would meet with the architect immediately, review the mechanical and restroom locations and return proposed revisions. Town officials asked the district to present alternatives that meet the town’s setbacks and clear‑view requirements and to identify whether the architect or engineer would cover redesign costs if the plans fail to meet code. Bids opening the next day were mentioned repeatedly as a scheduling constraint.

Why it matters The discussion affects a building that will serve roughly 250 elementary students daily and will be used for community events. The town and school board each said they want to complete a durable campus that meets the community’s program needs while maintaining public safety, compliance with state law and equitable enforcement of town codes for all property owners.

Next steps and public follow‑up The superintendent committed to asking the architect for alternate layouts after the meeting and to report back to the town. Town staff said they will not grant a formal variance under the current facts and asked for stamped design options that show setbacks in compliance with municipal code or documentation assigning responsibility for redesign costs. The council and planning‑and‑zoning members said they expect a follow‑up meeting once the architect provides stamped alternatives.

(Reporting note: meeting discussion was technical and largely deliberative; no formal motions or votes were recorded during this session.)